Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J AOAC Int ; 107(1): 103-111, 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-37698980

RESUMO

BACKGROUND: The AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals issued a call for methods for the determination of fluoride in infant formula. Standard Method Performance Requirement (SMPR®) 2014.016 was approved. OBJECTIVE: A single-laboratory validation (SLV) of a fluoride ion-selective electrode (F-ISE) method was completed. METHODS: Five powder samples were reconstituted, and hydrochloric acid was added to dissolve and release any bound fluoride. Samples included infant and adult nutritional products made from milk, whey, or soy, containing intact, partially hydrolyzed, or hydrolyzed proteins. Sodium citrate buffer was added to complex any interfering ions and adjust pH and ionic strength. Samples were analyzed in duplicate over 6 days using F-ISE. RESULTS: Results were calculated based on one of two least-squares (log fit) standard curves (0.02 to 0.1 µg/100 g or 0.1 to 2.0 µg/100 g). The LOQ for the method was determined to be 3.3 µg/100 g, which was far below the minimum analytical value of 30 µg/100 g required in the SMPR. The fluoride concentrations ranged from approximately 3 to 14 µg/100 g reconstituted powder and the intermediate precision, RSDr, ranged from 0.7 to 12.4%. Although all of these results are out of scope for the SMPR due to their low fluoride, it should be noted that the RSDr for formulas with fluoride concentrations ranging from approximately 9 to 14 µg/100 g ranged from 0.7 to 4.3%, and the RSDr for the two formulas with fluoride concentrations at or below the theoretical detection limit of the method were only approximately10 and 12.4%. Recoveries ranged from 94 to 98% for samples spiked at three levels with NIST-traceable standard solutions, meeting the SMPR. CONCLUSION: The F-ISE method meets the SMPR and was adopted as a First Action Official MethodSM. HIGHLIGHTS: The fluoride ion-selective electrode method presented here is affordable and easy to run. The addition of acid to the samples dissolves any minerals which may bind the fluoride.


Assuntos
Leite , Leite de Soja , Humanos , Lactente , Adulto , Animais , Fluoretos , Água , Pós , Eletrodos Seletivos de Íons , Fórmulas Infantis , Alimentos Formulados
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...